April Sale - Get 10% Off Orders Over £100. Use Code "APR24" At Checkout - Offer Lasts Until End Of April

Video

Binder - MK 115 Environmental Test Chamber For Complex Temperature Profiles 9020-0375

Loading...

Binder - MK 115 Environmental Test Chamber For Complex Temperature Profiles 9020-0375

Product Information:

The BINDER environmental simulation chamber of the MK series is suitable for heat or cold testing between -40 °C and 180 °C (-40 °F and 356 °F). The APT.line™ preheating chamber technology uniquely simulates a natural environment. For cyclical temperature testing, this environmental simulation chamber is a smart alternative to complex individual solutions.


Please contact sales office for quotation
  • Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results 
  • Temperature range of -40 °C to 180 °C (-40 °F to 356 °F) 
  • MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments 
  • User friendly LCD screen 
  • Easy-to-read menu guide 
  • Integrated electronic chart recorder 
  • Variety of options for the graphic display of process parameters 
  • Real time clock 
  • Adjustable ramp function via program editor 
  • Access port Ø 80 mm (3.15 inch), top 
  • Heated viewing window with LED interior lighting 
  • Temperature safety device class 2 (DIN 12880) with visual and audible temperature alarm 
  • RS 422 interface for communication software APT-COM™ DataControlSystem 
  • 1 stainless steel rack 
  • BINDER technical specification conformance certificate 
  • BINDER Communication software APT-COM™ 3 Basic Edition 
  • BINDER test certificate 
Options
  • Access ports with silicone plug 30, 50, 80, 100, 125 mm (1.18, 1.97, 3.15, 3.94, 4.72 inch) 
  • Securing elements for additional fastening of racks (1 set of 4 pieces) 
  • Keyboard lock 
  • Analog temperature output, 4-20 mA, with 6-pin DIN socket (output not adjustable) 
  • Factory calibration certificate. Measurement in center of chamber at 150 °C (302 °F) or at specified testing temperature 
  • Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature 
  • Additional measuring channel for digital display of specimen temperature, with flexible PT 100 temperature sensor. Measuring data recorded through device interface 
  • Data Logger Kit T 220: For the continuous temperature recording of -90 °C to 220 °C (-130 °F - 428 °F). Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit 
  • Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) 
  • Rack, stainless steel 
  • Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces), max. load 70 kg (154 lbs.) 
  • Shelf, perforated, stainless steel 
  • Notch-type access port in door, 100 x 35 mm (3.93 x 1.38 inch) 
  • Temperature safety device for preventing too low and high temperatures, class 2 
  • Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 3 relay outputs via 3 of the programmable controller’s controller contacts 
  • RS 422 interface 
  • Locking door handle with key 
More Information
General Specifications
Exterior dimensions
  • Width (incl. 18 mm (0.71 inch) access port with plug) (mm/inch) 1000 / 39.4 
  • Height (incl. casters) (mm/inch) 1725 / 67.9 
  • Depth (incl. door handle, I-triangle, connection 55 mm (2.17 inch)) (mm/inch) 915 / 36.0 
  • Wall clearance, side (mm/inch) 200 / 7.9 
  • Wall clearance, rear (mm/inch) 300 / 11.8 
  • Viewing window width (mm/inch) 288 / 11.3 
  • Viewing window height (mm/inch) 222 / 8.7 
  • Number of doors (ea.) 1 
Interior dimensions
  • Width (mm/inch) 600 / 23.6 
  • Height (mm/inch) 480 / 18.9 
  • Depth (mm/inch) 400 / 15.8 
  • Interior volume (l/cu.ft.) 115 / 4.1 
  • Racks (number standard/max.) 1 / 4 
  • Load per shelf (kg/lbs.) 30 / 66 
  • Permitted total load (kg/lbs.) 60 / 132 
  • Weight (empty) (kg/lbs.) 260 / 574 
Temperature data
  • Temperature range (°C/°F) -40 - 180 / -40 - 356 
  • Temperature variation (±K) 0.1 - 2.0 
  • Temperature fluctuation (±K) 0.1 - 0.5 
  • Mean warm-up rate acc. to IEC 60068-3-5 (°C/min.) 5.3 
  • Mean cooling rate acc. to IEC 60068-3-5 (°C/min.) 5.0 
  • Heat compensation, max. (W) 2000 
Electrical data 
  • IP protection class acc. to EN 50529 IP 20 
  • Voltage (± 10 %) 50 Hz (V) 400, 3 N ~ 
  • Nominal power (kW) 3.5 
  • Energy consumption at 20 °C (68 °F) (W) 1) 650 
  • Noise level (approx. dB(A)) 62 
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber.All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

Write Your Own Review
You're reviewing:Binder - MK 115 Environmental Test Chamber For Complex Temperature Profiles 9020-0375
Your Rating
Customer Questions
No Questions
Did you find what you were looking for?
SKU
190-MK115

Phone: +44 02380 650065

9020-0375


  • UK Delivery

    Free*/£9.50

    *FREE delivery on orders over £50.

  • International Delivery

    International DHL delivery available.

  • Returns

    For more information on returns Click here.

Request pricing or a demonstration now!

Speak to us about your requirements and we'll give you a competitive price. Arrange an onsite visit if you're unsure whether a product offers the best solution for your business's needs.

Join our mailing list