Binder - FP 240 Material Test Chamber With Mechanical Convection 9010-0263
Product Information
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads.
Performance characteristics
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads.
Performance characteristics
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
- Temperature range from 5 °C above ambient temperature to 300 °C
- MP controller with 2 programs with 10 sections each, or alternatively 1 program with 20 sections
- The time of an individual program step can be set to max. 99.59 hours or 999.59 hours. This adjustment applies to all program sections.
- Integrated weekly program timer with real-time function
- Adjustable ramp function via program editor
- Digital temperature setting with an accuracy of one degree
- Adjustable fan speed
- Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
- Elapsed time indicator
- Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
- RS 422 interface for use with APT-COM™ DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
- Units up to 115 liters are stackable
- 2 chrome-plated racks included
- BINDER test confirmation
- Access ports with silicone plug, 10, 30, 50, 100 mm
- HEPA fresh-air filter, Class H 14 (according to EN 1822, min. 99.999% for 0.3 µm particles)
- Securing elements for additional fastening of racks (1 set of 4 pieces)
- Anti-slip rubber pads for safe stacking (1 set of 4 pieces)
- Measurement of air exchange rate according to ASTM D5374, with definition and protocol according to ambient temperature (measurement in factory)
- Temperature measurement acc. to DIN 12880 (27 measuring points) at 150 °C or at specified temperature with measuring protocol and certificate
- Factory calibration certificate. Measurement in center of chamber at 150 °C (302 °F) or at specified testing temperature
- Extension to factory calibration certificate. Each additional measurement at additional measuring point or temperature
- Additional measuring channel for digital display of specimen temperature with flexible PT 100 temperature sensor, measured data recorded via RS 422 interface
- Independent temperature safety device class 3.1 (DIN 12880) with optical alarm
- Analog output for temperature 4 - 20 mA with 6-pin DIN socket (output not adjustable)
- Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller's contacts. Zero-voltage relay outputs can be switched on and off either automatically and manually
- Data Logger Kit T 350: For continuous temperature recording of 0 °C to 350 °C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for mounting to the BINDER unit
- Data Logger converter cable RS 232 to USB 2.0
- Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable
- Rack, chrome-plated
- Rack, stainless steel
- Reinforced rack, stainless steel, with 1 set of fasteners (4 pieces), max. load 70 kg
- Shelf, perforated, stainless steel
- Locking door handle with key
- Door gasket, FKM (Viton)
- Reinforced inner chamber, including 2 reinforced racks (maximum total load 270 kg, max. load per rack 70 kg)
- 2 doors each with window 350 x 240 mm and interior lighting (30 W)
- Increased air-exchange rate through high-performance fan