With a maximum temperature of 300 °C and comprehensive programming options, the M series from BINDER is ideally suited for material and aging testing. The high-performance fan ensures fast heating
Performance characteristics
With a maximum temperature of 300 °C and comprehensive programming options, the M series from BINDER is ideally suited for material and aging testing. The high-performance fan ensures fast heating
Performance characteristics
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
- Temperature range from 5 °C above ambient temperature to 300 °C
- MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- User-friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real-time clock
- Adjustable ramp function via program editor
- Program-controlled ventilation flap
- High air-exchange rate through high-performance fan
- Adjustable fan speed
- Exhaust duct Ø 50 mm
- Temperature safety device class 2 (DIN 12880) with visual alarm
- Printer and communication interface RS 422 for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-COM™ DataControlSystem software
- Units up to 115 liters are stackable
- 2 chrome-plated racks included
- BINDER test confirmation
- Access ports with silicone plug, 10, 30, 50, 100 mm
- Securing elements for additional fastening of racks (1 set of 4 pieces)
- Anti-slip rubber pads for safe stacking (1 set of 4 pieces)
- Keyboard lock
- HEPA fresh-air filter, Class H 14 (according to EN 1822, min. 99.995% for 0.1-0.3 µm particles)
- Measurement of air change rate according to ASTM D5374, with definition and protocol according to ambient temperature (measurement in factory)
- Analog temperature output 4 - 20 mA with 6-pin DIN socket (output not adjustable)
- Additional PT 100 temperature sensor, flexibly installed with external connection, includes LEMO connector (3-pin)
- Additional measuring channel for digital display of specimen temperature with flexible PT 100 temperature sensor, measured data recorded via RS 422 interface
- Temperature measurement acc. to DIN 12880 (27 measuring points) at 150 °C or at specified temperature with measuring protocol and certificate
- Factory calibration certificate. Measurement in center of chamber at 150 °C (302 °F) or at specified testing temperature
- Extension to factory calibration certificate. Each additional measurement at additional measuring point or temperature
- Data Logger Kit T 350: For continuous temperature recording of 0 °C to 350 °C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for mounting to the BINDER unit
- Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable
- Rack, chrome-plated
- Rack, stainless steel
- Shelf, perforated, stainless steel
- Locking door handle with key
- Door gasket, FKM (Viton)
- Door with window 320 x 260 mm and interior lighting (15 W)
- Inert gas connection (gas inlet and outlet; Ø 10 mm).We also recommend the mostly gas-tight version option
- Mostly gas-tight version
- Base on castors